6. คำอธิบายหน่วยสมรรถนะ (Description of Unit of Competency)
          This unit of competency requires the application of hand skills, the use of maintenance publications and basic knowledge of air conditioning systems with steam pump to inspect, test and troubleshoot systems, and for removing and installing the mechanical and electrical components of the system during the performance of scheduled or unscheduled maintenance. Maintenance can be done individually or as part of a team.Compliance with applicable regulations is required where refrigerant evacuation and recharging is performed.          Applications include all aircraft vapour cycle air conditioning systems and components.

7. สำหรับระดับคุณวุฒิ
1 2 3 4 5 6 7 8

8. กลุ่มอาชีพ (Sector)
10 Aircraft Mechanics

9. ชื่ออาชีพและรหัสอาชีพอื่นที่หน่วยสมรรถนะนี้สามารถใช้ได้ (ถ้ามี)
101 Aircraft Maintenance: Airplane102 Aircraft Maintenance:Helicopter

10. ข้อกำหนดหรือกฎระเบียบที่เกี่ยวข้อง (Licensing or Regulation Related) (ถ้ามี)
ICAO Doc 7192 / EASA Part 66

11. สมรรถนะย่อยและเกณฑ์การปฏิบัติงาน (Elements and Performance Criteria)
หน่วยสมรรถนะย่อย (EOC) เกณฑ์ในการปฏิบัติงาน (Performance Criteria) รหัส PC
(ตามเล่มมาตรฐาน)
รหัส PC
(จากระบบ)
101415.01 Inspect vapour cycle air conditioning systems. 101415.01.01 Isolation tags already attached to the system or relatedsystems are checked and aircraft/engine configured forsafe system inspection and operation in accordance with applicable maintenancemanual 101415.01.01 71121
101415.01 Inspect vapour cycle air conditioning systems. 101415.01.02 Vapour cycle airconditioning systems are visually or physically checked for external andinternal signs of defects in accordance with applicable maintenance manualwhile observing all relevant work health and safety (WHS) requirements, including the use of material safety datasheets (MSDS) and items of personalprotective equipment (PPE) 101415.01.02 71122
101415.02 Test vapour cycle air conditioning systems. 101415.02.01 Aircraft and system are correctly prepared in accordancewith applicable maintenance manual 101415.02.01 71123
101415.02 Test vapour cycle air conditioning systems. 101415.02.02 Vapour cycle airconditioning system is tested in accordance with prescribed test proceduresto establish serviceability and correct function in accordance withapplicable maintenance manual 101415.02.02 71124
101415.03 Troubleshoot vapour cycle air conditioning systems. 101415.03.01 Available information from maintenance documentation andinspection and test results is used, where necessary, to assist in faultdetermination , maintenance manual fault diagnosis guide and logicalprocesses are used to ensure efficient and accurate troubleshooting to linereplacement level 101415.03.01 71125
101415.03 Troubleshoot vapour cycle air conditioning systems. 101415.03.02 Specialist advice isobtained, where required, to assist with the troubleshooting process Vapourcycle air conditioning system faults are located and the causes of the faultsare clearly identified and correctly recorded in maintenance documentation,where required and fault rectification requirements are determined to assistin planning the repair 101415.03.02 71126
101415.04 Remove vapour cycle air conditioning system components. 101415.04.01 Aircraft and vapour cycle air conditioning system isrendered safe in accordance with the applicable maintenance manual andisolation tags are fitted, where necessary, to ensure the safety of personneland freedom from damage during component removal , where refrigerantevacuation is necessary, evacuation is performed in accordance withregulatory requirements and maintenance manual procedures 101415.04.01 71127
101415.04 Remove vapour cycle air conditioning system components. 101415.04.02 Component removal iscarried out in accordance with the applicable maintenance manual whileobserving all relevant WHS requirements, including the use of MSDS and itemsof PPE, component is tagged and prepared for transport or storage inaccordance with the specified procedures. Requiredmaintenance documentation is completed and processed in accordance withstandard enterprise procedures 101415.04.02 71128
101415.05 Install vapour cycle air conditioning system components. 101415.05.01 Component to be installed is checked to confirm correctpart or model numbers, modification status and serviceability, andinstallation is carried out in accordance with the applicable maintenancemanual while observing all relevant WHS requirements, including the use ofMSDS and items of PPE 101415.05.01 71129
101415.05 Install vapour cycle air conditioning system components. 101415.05.02 Vapour cycle airconditioning system is recharged with refrigerant, where necessary, inaccordance with maintenance manual procedures and regulatory requirements. Vapour cycle air conditioning system is tested for correctfunction and freedom from refrigerant leaks if system recharging has beenperformed, and required maintenance documentation is completed and processedin accordance with standard enterprise procedures 101415.05.02 71130

12. ความรู้และทักษะก่อนหน้าที่จำเป็น (Pre-requisite Skill & Knowledge)


101309 Remove and install miscellaneous aircraft electrical hardware/components




101403 Minor repair for aircraft electrical components or parts 


13. ทักษะและความรู้ที่ต้องการ (Required Skills and Knowledge)

(ก) ความต้องการด้านทักษะ

N/A

(ข) ความต้องการด้านความรู้

N/A

14. หลักฐานที่ต้องการ (Evidence Guide)


(a) Performance Evidence




          Evidence required to demonstrate competency in this unit should be of interest and meet all requirements of the elements and performance criteria under the specified conditions assessment, and should include:




          • applying relevant WHS procedures, including the selection and use of applicable PPE and MSDS




          • complying with regulatory requirements regarding the de-gassing of vapour cycle air conditioning systems




          • using relevant maintenance documentation and aircraft manuals




          • recognising external and internal signs of defects in vapour cycle air conditioning systems and system components through visual/physical inspection




          • testing of vapour cycle air conditioning system operation, be able to operate systems and leak testing equipment, monitor indications and recognise correct function




          • using specialist equipment to evacuate and recharge refrigerant




          • using fault diagnosis guides and equivalent data to accurately and efficiently troubleshoot the causes of unserviceabilities in vapour cycle air conditioning systems, clearly recording details and identifying the required rectification actions




          • correctly removing and installing vapour cycle air conditioning system electrical and mechanical components.




          The inherent underlying skills to this unit should be transferable across a range of inspection, testing, and troubleshooting tasks removal and installation (including the timely intervention of supervisor or other trades) associated with the systems and components of air conditioning steam cycle. It is essential that the testing procedures system takes into account all safety precautions associated with the operation and system testing vapor cycle air conditioning, and regulations related to the evacuation and recharge refrigerant is strictly observed. Ability to interpret procedures and specifications (allowable limits) inspection and apply them in practice is essential.




          This is demonstrated by the application through a series of air conditioning systems steam cycle of the aircraft.




(b) Knowledge Evidence




          Evidence required to demonstrate competency in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria and include basic knowledge of:




          • WHS procedures associated with vapour cycle air conditioning system maintenance, including the selection and use of PPE




          • how to obtain applicable MSDS




          • regulations applying to the evacuation and recharging of refrigerant




          • fault diagnosis techniques




          • vapour cycle air conditioning system layout and operation




          • vapour cycle air conditioning system electrical and mechanical component operation:




          • compressor




          • condenser




          • receiver dryer




          • thermal expansion valve




          • evaporator




          • magnetic clutch and drive system:




          • belt




          • power takeoff




          • electric motor




          • hydraulic motor




          • pneumatic




          • condenser extension and retraction system




          • blower




          • throttle system shutoff




          • temperature control system




          • refrigerant used in aircraft vapour cycle air conditioning systems




          • lubricants used in compressors




          • equipment used to test systems and evacuate and recharge refrigerant




          • procedures for evacuating and recharging system refrigerant




          • refrigerant leak testing techniques and equipment




          • removal and installation procedures for vapour cycle air conditioning system components




          • vapour cycle air conditioning system maintenance requirements




          • relevant maintenance manuals




          • relevant regulatory requirements and standard procedures.




(c) Assessment  recommendation




          N/A




Assessmen  methods




          N/A


15. ขอบเขต (Range Statement)


(a) Recommendation




          This field allows different environments and working conditions that can affect the performance. Essential operating conditions that may be present (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) are included.




          Vapour cycle air conditioning systems include:




          • Refrigeration system compressor, condenser, receiver dryer, thermal expansion valve and evaporator




          • Magnetic clutch and drive system (belt, power take-off, electric motor, hydraulic motor or pneumatic as applicable)




          • Condenser extensionand retraction system




          • Blower




          • Throttle system shutoff




          • Temperature control system




          Procedures and requirements include:




          • Industry standard procedures specified by manufacturers, regulatory authorities or the enterprise




(b) Description




          N/A


16. หน่วยสมรรถนะร่วม (ถ้ามี)
N/A

17. อุตสาหกรรมร่วม/กลุ่มอาชีพร่วม (ถ้ามี)
N/A

18. รายละเอียดกระบวนการและวิธีการประเมิน (Assessment Description and Procedure)


          • The assessment are composed of paper exams , interviews, and practical demonstrations, which the paper exam is the main testing. The selection of interviews and practical demonstrations are depending on the assessors’ judgment.Competence should be assessed in the work environment or simulated work environment using tools and equipment specified in the maintenance documentation. It is also expected that general purpose tools and test equipment found in most routine situations would be used if necessary.




          • The application of test procedures and functional checks must show basic knowledge of the operation and regulation relating to the refrigerant fluid system. Vapor cycle air conditioning basic knowledge of system operation, the relationship of the individual components and the links with other systems will be needed to complete the proof of the ability to carry out checks of the engine control system and troubleshoot the system within aircraft / research guide of system failures before undertaking any action. The work plan should take account of safety and quality requirements in compliance with industry and regulatory standards.




          • The following conditions assessment are the requirements of regulators and stakeholders and maintenance must be strictly observed.




          • A person can not be assessed as competent until it can be demonstrated to the satisfaction of the assessor in the workplace that the relevant elements and performance criteria of competence unit are achieved under the supervision routine on a system and at least one (1) each of the following components:




          • compressor refrigeration system, condenser, receiver dryer, a thermal expansion valve and the evaporator




          • magnetic clutch and drive system (belt, PTO, electric, hydraulic or pneumatic motor as appropriate)




          • condenser extension and retraction system




          • blower




          • stop throttle system




          • temperature control system.



          • This are established through the records in the newspaper industry experience and yield or, where appropriate, a guide on evidence of equivalent industry (for details refer to the Companion Volume Assessment Guidelines )